Overpressure valves for shelters and protected sites
BVNC overpressure valves are normally closed: they maintain or control the pressure difference in the shelter by releasing air from the sealed shelter, while protecting against external blast wave pressure.

Durable overpressure valves
For shelters and industry — to control pressure differences.
Features
BVNC valves are designed for civil defence shelters, bunkers, safe rooms and other protected rooms.
- A wide choice of models for different air flows.
- Automatic operation — protection against external blast waves.
- Release air in a controlled way when overpressure reaches the required level.
- Extremely durable, work across a wide temperature range and resist corrosion.
- Installed in ventilation openings or ducts.

PRV 800 — pressure differential control valve
An adjustable valve for maintaining and controlling the pressure difference between rooms (e.g. airlocks) or between the shelter and the outside. Adjustable flow 50–800 m³/h.

BVNC 40 — overpressure valve
A normally closed valve that maintains and controls the pressure difference in the shelter and protects the rooms inside from external blast wave pressure. Nominal flow 40 m³/h at 200 Pa.

BVNC 300 — overpressure valve
A normally closed valve that maintains and controls the pressure difference in the shelter and protects the rooms inside from external blast wave pressure. Nominal flow 300 m³/h at 200 Pa.

BVNC 600 — overpressure valve
A normally closed valve that maintains and controls the pressure difference in the shelter and protects the rooms inside from external blast wave pressure. Nominal flow 600 m³/h at 200 Pa.

BVNC 1500 — overpressure valve
A normally closed valve that maintains and controls the pressure difference in the shelter and protects the rooms inside from external blast wave pressure. Nominal flow 1500 m³/h at 200 Pa.

BVNC 2100 — overpressure valve
A normally closed valve that maintains and controls the pressure difference in the shelter and protects the rooms inside from external blast wave pressure. Nominal flow 2100 m³/h at 200 Pa.

BVNC 3300 — overpressure valve
A normally closed valve that maintains and controls the pressure difference in the shelter and protects the rooms inside from external blast wave pressure. Nominal flow 3300 m³/h at 200 Pa.
Have a project?
Tell us about the site, the openings or the protection level you need — we will suggest the right solution.
Compliance with STR 2.07.02:2024
Lithuania's STR 2.07.02:2024 requires blast shelters (slėptuvės) to filter air with certified filters and keep the protected rooms under overpressure, while in shelters (priedangos) protection against harmful substances is installed at the client's request. We select ventilation, filtration and valve solutions according to the type of facility and the project.