Blast hatches for shelters
Blast-resistant shelter hatches are a vital part of a shelter's protection, guarding the emergency entry and exit against the destructive force of a blast wave. We offer a wide choice of hatches to various national civil defence and international standards, as well as custom solutions.
We supply steel, concrete, composite and combined hatches, single or double leaf, for retrofits or casting into concrete — side-opening (vertical installation) or top-opening (horizontal installation). They protect against blasts, fragments, bullets, fire and more. Some hatches have a rubber seal for gas-tightness.

Side- and top-opening hatches
Blast-resistant, gas-tight, bulletproof and other special hatches.

SL-1 blast hatch (Finnish standard, opens outwards)
SL-1 and SL-1S shelter hatches meet the Finnish S1 shelter standard. SL-1 hatches open outwards (against the direction of the blast wave).

HS-1 blast hatch (Finnish standard, opens inwards)
HS-1 and HS-1S shelter hatches meet the Finnish S1 shelter standard. HS-1 hatches open inwards (in the direction of the blast wave).

SU-III-INW blast hatch (opens inwards)
SU-III-INW shelter hatches meet Central and Eastern European shelter standards and are designed for a blast wave pressure of 440 kPa (4.4 bar); they open inwards (in the direction of the blast wave).

SU-IVR blast hatch (opens outwards)
SU-IVR shelter hatches are designed for a blast pressure of >100 kPa (1 bar) in line with current technical standards for civil defence shelters.

SU-III blast hatch (opens outwards)
SU-III shelter hatches are designed for a blast pressure of >440 kPa (4.4 bar) (opening outwards) in line with current technical standards for civil defence shelters.

SU-I blast hatch (opens outwards)
SU-I shelter hatches are designed for a blast pressure of >900 kPa (9 bar) (opening outwards) in line with current technical standards for civil defence shelters.

SU-type top-opening hatch
SU-type hatches with gas struts are designed to open from above. SU-IVR, SU-III and SU-I hatches can be fitted with a lifting mechanism so that they can be installed horizontally.

SU-III RWRT watertight top-opening hatch
SU-III RWRT shelter hatches are designed for a blast pressure of up to 440 kPa (4.4 bar) (opening from above) in line with current technical standards for civil defence shelters.
Compliance with STR 2.07.02:2024
Lithuania's STR 2.07.02:2024 sets requirements for shelter entrances — door resistance to blast shock waves and fire, and for blast shelters (slėptuvės) also gas-tightness. We select doors, hatches and gates according to the type of facility (blast shelter, collective protection building or shelter) and the project design.
Let's talk about your protection
We reply within one working day. Tell us what you want to protect — we will help you choose a solution.